Type C AmbulanceEN 1789 · Advanced Life Support

Mobile Intensive Care Unit

Designed and equipped for the transport, advanced treatment, and monitoring of patients in accordance with the EN1789 standard. As a special requirement, it features clearance around the head of the stretcher which, together with the lateral movement of the stretcher base, allows for patient care from any position.

KEY FEATURES

CARLA 4.0 Technology
Cutting-Edge Technology
CARLA 4.0 Touch Control The CAN BUS function control system via touchscreens is standard across all ambulance types. The cabin (7-inch) and patient area (10-inch) interfaces can be supplemented with MMI controls (4.3-inch) in any location. The electronics are custom-programmed according to the specific requirements of each conversion. Discover CARLA 4.0
Emergency Signaling
Next-Generation Emergency Signaling
RLAJ1, RLAJ2 and RLAJ4 RLA offers a wide range of emergency light signaling solutions. RLAJ1 is the comprehensive solution covering the entire ambulance roof. The front RLAJ4 and rear RLAJ2 modules can be used together or combined with lightbars or other systems. Discover RLAJ1
Ergonomic Treatment Area
Ergonomic Space
EN 1789 Treatment Area The combined use of a stretcher base with lateral/longitudinal displacement, along with the versatile range of RLA seating, allows for patient care from any position. Swivel side seats can be oriented towards the stretcher or in the direction of travel. Longitudinal displacement or the head-end seat on rails allows for distance adjustment for optimal care.
Electromedical Equipment Wall
Electromedical Equipment Wall
Rail-Mounted Brackets Electromedical devices are installed on sliding brackets on rails. This allows each element to be placed in the optimal position. The system supports original or custom-made brackets by RLA. The rails are complemented by strategically located power and oxygen outlets, as well as LED lighting bars. Read more
RLA Customized Solutions
Customized Solutions
Bespoke Design A multidisciplinary team of engineers is assigned to every individual project or large fleet prototype. Every detail of the ambulance is defined in collaboration with the client. Our R&D Departments, supported by the extensive machinery available at our facilities, allow us to develop and manufacture the innovative solutions required by the specifications. RLA Facilities
10G Crash Test Safety
Safety as a Starting Point
10G Crash Test To guarantee the safety of the patient and occupants, strategic structural reinforcements are applied to the components of the patient compartment. The result is backed by 10G Crash Tests in 5 directions as required by the European Standard EN 1789. Certifications
Comfortable Patient Area
Comfortable Patient Area
Thermal and Acoustic Insulation The sanitary cell is completely insulated to improve interior thermal stability and optimize climate control efficiency. Additionally, the compartment remains free from external noise, staying below 77 dB(A) at 120 km/h as specified by European Standard EN 1789.
Reliable Materials
Reliable Materials
Antibacterial, waterproof, and flame retardant To enhance safety, all interior materials are flame retardant according to ISO 3795:1989. The use of plastic board or MDF, combined with the interior surface finishes of the floor, furniture, and ceiling, results in a water-repellent structure that prevents pathogen buildup.
Seamless lacquered finish for ambulance furniture
Seamless Finish
Full interior lacquering, joint sealing The interior lacquering applied to the entire furniture structure seals the joints and prevents the filtration of liquids and small particles. Ambulance disinfection is much more effective and it is resistant to continuous cleaning. Learn More
Non-slip waterproof technical flooring with epoxy paint
Non-Slip Waterproof Technical Floor
Sprayed epoxy coating Epoxy paint is sprayed over the entire floor up to a minimum baseboard height of 5 cm. This creates a watertight, non-slip ambulance base that is easy to disinfect. Learn more
Direct LED lighting and adjustable spotlights
Direct Lighting
Interior Ceiling LED bars along the entire ceiling provide illumination for the entire patient compartment. Adjustable cold-light ceiling spotlights focus on specific areas to assist technicians. The luminosity in the treatment area exceeds 1,650 lx and the color temperature ranges between 3,800 K and 4,300 K, following Standard EN 12464-1:2011. Learn more
HVAC system for ambulances including air conditioning and heating
Climate Control for All Situations
Air Conditioning and Heating CARLA 4.0 efficiently manages the climate control system to automatically reach the selected temperature. Manual mode can be used for more precise ventilation flow. Other options are also available, such as diesel stationary heating or electric climate control when the ambulance is connected to the mains.

A WORLD OF POSSIBILITIES

Technical Data

MERCEDES-BENZ Sprinter
MAN TGE
VOLKSWAGEN Crafter
RENAULT / RENAULT TRUCKS Master
FORD Transit
PEUGEOT Boxer
FIAT Ducato
OPEL / VAUXHALL Movano
IVECO Daily
Other Brands Inquire
This website uses its own and third-party cookies to offer you a better experience and service. Navigation implies acceptance of them. ACCEPT | More information